Radiator tails and extensions explained: measure pipe centres and valve gap, choose extension length and thread, seal correctly and know when to move pipes.
When a new radiator is a little narrower than the old pipe spacing, a valve extension or longer radiator tail can bridge the gap at the connection. Measure carefully, use matching threads and move the pipework instead if the gap is large or the joint would be strained.
Measure the problem
- Measure existing pipe centres, centre to centre.
- Find the new radiator's required centres, adding its valve allowance.
- Subtract and divide the gap between the two ends.
- Check height of the connections and distance from the wall too.
Valves add to the overall width of a radiator, and the allowance differs between valve ranges. Take the figure from the drawing for the exact valves you are fitting, not from the radiator width alone.
Parts
| Part | Use |
|---|---|
| Radiator tail | Joins valve union to radiator tapping |
| Rigid extension | Adds fixed length between tail and valve |
| Telescopic extension | Adjusts within a stated range |
| Reducing adaptor | Matches a different tapping size |
Common radiator tappings are half inch BSP, but check both. Stelrad lists nickel-plated brass extension pieces with sealing washers in 20, 30 and 40 mm lengths. Do not assume a flexible or telescopic part will absorb a difference unless its maker states the range. A longer assembly puts more leverage on the radiator thread and the valve, so use one correctly sized part rather than a stack of short ones.
Limits
An extension fixes horizontal shortfall. It cannot correct a radiator that sits at the wrong height or depth, nor pipes that are out of line. If pipes would need bending sharply, re-route them. Visible long extensions can look awkward and catch cleaning cloths.
Before work
- Switch off heating and let water cool.
- Protect the floor; radiator water is dirty.
- Close both valves, noting turns on the lockshield.
- Vent and drain the radiator.
- Check whether the valves actually seal.
Leave gas boiler controls and gas pipes to a Gas Safe registered engineer. Sealed systems need correct refilling and pressure, so know your system before draining.
Fitting
- Clean the tapping.
- Apply thread tape or compound as the part maker requires; parts with their own seal may need none. Stelrad's installation sheet, for example, says its supplied vent and blanking plug need no tape or sealant.
- Screw the tail in with the correct tail key, without rounding it.
- Fit extension and union nut by hand first.
- Offer up the radiator and check the valve meets squarely.
- Tighten while holding the valve body.
Refill
Open valves, bleed air, restore system pressure if applicable and check each joint cold and then hot. Rebalance by returning the lockshield to its noted position. Treat the water with inhibitor if a significant amount was replaced.
Weeping joint
A leak at the tapping usually needs the tail resealed. A leak at the union points to alignment or seal. Do not simply force it tighter.
Choosing to move pipes
Wait until the new radiator and valves are in the home before altering pipes, because small manufacturing differences can change the final position. New pipes cost more but give a neat, unstressed fit. Ask for both options.
Send pipe centres, the radiator model and valve photos via the contact form, with images emailed against your reference.
Tidy finish
Choose chrome or matching extensions where they will be seen, and line up both ends so they look intentional. Floor collars can hide small gaps around pipes. Do not box in a union or extension where it cannot be checked, since a slow weep may go unnoticed for months and rust the radiator, mark the floor or lower system pressure. Look at the joints again after the first week of heating, when expansion and cooling have had a chance to show any weakness.
What to measure before ordering a radiator
Where the radiator is not yet bought, picking a width that suits the existing centres avoids extensions altogether. Check the height, brackets, depth from wall and tapping positions at the same time, and compare heat output for the room, as covered in radiator sizing.
Questions people ask
How much can an extension take up?
Only as much as the part is made for. Stelrad lists 20, 30 and 40 mm extension pieces for its radiators. Larger gaps are better solved by moving pipes.
Do I need to drain the system?
Changing tails means draining the radiator and, depending on the valves, possibly part or all of the system.