Radiator BTU room sizing explained: room heat loss, walls, windows and insulation, watts and BTU conversion, ΔT50 ratings and low temperature systems.
Radiator sizing starts with how much heat a room loses, then picks a radiator whose output at your system's water temperature meets it. A calculator that knows the room dimensions, outside walls, windows and insulation is far better than a rule per square metre.
What drives heat loss
- floor area and ceiling height;
- number and construction of outside walls;
- window size and glazing;
- floor and roof or rooms above and below;
- draughts and ventilation;
- the temperature wanted in that room.
A Stelrad technical sheet points to the maker's own heat loss calculator programme for sizing. For a new heating system or heat pump, a full calculation by a competent designer is needed.
Watts and BTU
Stelrad's glossary gives one watt as 3.412 BTU per hour. So a 1,500 W radiator is about 5,100 BTU per hour.
Delta T
Output depends on the difference between average water temperature and room air. The UK standard rating is ΔT50. A Stelrad technical sheet shows that for other temperatures you multiply the ΔT50 figure by an operating factor; in its example, 2,000 BTU per hour at ΔT50 becomes 1,030 at ΔT30, a factor of 0.515. Working backwards, divide the required output by the factor, then choose from the standard tables.
| Operating condition | Effect |
|---|---|
| Conventional hot circuit near ΔT50 | Use catalogue figure |
| Lower temperature, including many heat pump designs | Much larger radiator for same heat |
The same table gives about 0.748 at ΔT40 and 1.267 at ΔT60, so a figure quoted at ΔT60 looks larger without producing more heat in your home.
Worked outline
- Calculator says the room needs 5,000 BTU per hour.
- Your system runs at ΔT30.
- Required ΔT50 rating = 5,000 / 0.515, about 9,700.
- Pick a radiator, or two, meeting that rating.
These numbers illustrate the method only.
Choosing the radiator
Compare single and double panels, convectors, vertical and column styles. Height, width and depth must fit the wall and pipes. A radiator under a window often counters draughts; furniture and thick curtains reduce output.
Pipes and boiler
A larger radiator holds more water and may need larger pipework or balancing. Whether the boiler can serve a larger load is a question for a Gas Safe registered engineer.
Check an existing room
If one room is cold, first look for air, closed valves, sludge or balancing problems before blaming size. Note the radiator's dimensions and type and look up its rated output.
Special cases
Bathrooms often want a higher temperature and towel rails give limited output. Open plan spaces may need several emitters. Extensions with large glazing need careful figures.
Sharing the details
For fitting a chosen size, send room measurements, radiator model and photos through the contact form, with files emailed against the reference. Heat design should come from a qualified designer.
Mistakes that distort results
Entering a room as having one outside wall when it has two, ignoring a bay window, or choosing glazing the home does not have changes the figure considerably. Measuring only floor area misses tall Victorian ceilings. Using the output of a radiator at the wrong temperature difference is the most expensive mistake, because the product looks adequate on paper and underperforms on the wall.
Record sheet
For each room note length, width, height, outside walls, window width and height, glazing type, what is above and below and the present radiator's size. Add how warm the room feels in cold weather. With that information a designer can check results quickly, and the same sheet helps compare radiators from different makers on equal terms.
Space limits
If the required output does not fit one position, consider a deeper panel, a second radiator or improving draught proofing and insulation before accepting an undersized one.
Questions people ask
What is a BTU?
A unit of heat. One watt is equivalent to about 3.412 BTU per hour.
Why do two radiator sites quote different outputs?
They may use different temperature differences. Compare at the same ΔT.