Column radiator installation: check filled weight, floor feet and wall stays, stud or masonry brackets, flow side, pipe centres, sealing and refilling.
Column radiators are heavy before they are filled, so plan support first: wall brackets, or feet on the floor with ties to the wall. Then confirm pipe positions, the flow connection and how the system will be drained and refilled.
Weigh up the support
A steel multi column radiator fitting guide shows several mounting options, including standard wall brackets, brackets for solid walls, brackets for stud walls, floor mounts and slip on feet. It pairs floor supports with wall ties, positioned to stop the radiator falling away, and increases the number of supports as the section count rises.
| Support | Check |
|---|---|
| Brackets on masonry | Sound material at every fixing |
| Brackets on studs | Studs or added timber where brackets land |
| Floor feet | Floor level, strong and clear of pipes |
| Wall ties | Fixed to something that resists a pull |
Add the water weight to the dry weight on the product sheet and have the structure checked if there is doubt. Underfloor heating pipes beneath the floor rule out drilling until their route is known.
Positions and pipes
The same guide gives pipe distances from the wall that vary with the number of columns and the mounting type, and sets the left to right centres as the radiator width plus the valves. Measure from your finished wall and floor, with the actual valves chosen. A new column radiator is often deeper than the panel it replaces, so check doors, skirting and furniture.
Flow side and bushes
The guide describes a diverter near one end and says the flow must be connected to that side. Its bushes use left and right hand threads, marked on one side, which are damaged easily if forced. It specifies a dry joint or no more than four turns of PTFE tape and rules out compounds and hemp. Treat these as that product's instructions.
Before draining
- Identify a sealed or open-vented system.
- Know the filling method and pressure.
- Check that old valves and drain points work.
- Obtain inhibitor to replace what you remove.
- Ask the managing agent if the heating is communal.
Installation order
- Cool and isolate the heating.
- Drain below the work.
- Fix brackets or prepare the feet, level and plumb.
- Prepare bushes, vent and plug.
- Lift with enough people; protect floor and paint.
- Secure brackets and ties before letting go.
- Connect valves without straining the pipes.
- Refill, bleed and check.
Commission
Fill slowly and inspect each section joint as well as the valves. Bleed, restore pressure if sealed, add inhibitor as directed and run hot. Check again after cooling. Balance the lockshields across the system.
Warning signs
Weeping between sections, movement at the feet, or repeated loss of pressure needs attention promptly. Do not hang heavy wet items on the top.
Handling
Two or more people should move a long unit. Keep it upright on soft supports, and do not lift by the vent or valve tails. Sectional radiators delivered joined can be strained if carried flat.
Reusing an old cast iron radiator
A reclaimed unit should be pressure tested and flushed by someone equipped to do it before it goes on a system, as old joints between sections can leak once heated and sludge can spread. Its tapping threads may need adaptors, its weight is considerably greater and its feet may not sit level on a modern floor. Old paint can contain lead, so avoid sanding it without precautions.
Getting help
Email the product drawing, wall and floor photographs and a picture of the filling point after a short note on the contact form. If the boiler needs attention as well, that part goes to a Gas Safe registered engineer.
Questions people ask
Do floor mounted column radiators need wall fixings?
Yes, one fitting guide supplies wall ties alongside floor feet so the radiator cannot fall away from the wall.
Can I use sealing paste on the bushes?
That guide forbids compounds and hemp on its bushes and limits PTFE tape. Follow your radiator's sheet.