Preview build. Not indexed.

Clearances around toilet, basin and shower

Published

Bathroom measurements and clearances: how to plan space around toilet, basin, bath and shower, check doors and heights, and test the layout before buying.

Measure the finished room, draw each fitting at its true size and leave the space a person needs to use and clean it. Test the layout with tape on the floor and the door open before ordering.

Record the room

  • Length and width at floor and 1 metre height.
  • Diagonals, to find walls that are not square.
  • Ceiling height and slopes.
  • Door width, swing and handle.
  • Window sill height and opening.
  • Soil pipe, radiator and sockets.
  • Allowance for new boards and tiles.

Use zones

Each fitting has a body zone in front of it. These working suggestions are starting points to test, not regulations:

Fitting Think about
Toilet Elbow room each side, space in front to stand
Basin Bending forward without hitting a wall
Bath Stepping in and kneeling beside it
Shower Entry opening and room to dry
Towel rail Reach from bath or shower without crossing wet floor

Zones may overlap if only one person uses the room at a time. Doors should not strike a person at the basin or trap someone who falls behind them.

Published standards

Approved Document M includes drawings of clear access zones for WCs, basins, baths and showers in homes built to its accessible categories, including limits on how a basin may intrude into a toilet zone: up to 200 mm for a hand rinse basin and 300 mm for a wash basin in its accessible and adaptable layouts. The same drawings keep radiators and towel rails clear of the access zones and let a basin zone extend underneath as far as the pedestal, unit or trap. They apply where the building regulations require that category, and are useful reference when planning for older or disabled users.

Door and extract

Approved Document F expects extract ventilation to outside in bathrooms and toilets, with intermittent rates of at least 15 litres per second for a bathroom and 6 for a room with a toilet only, where purge ventilation such as an opening window may be used instead. It places the fan as high as practicable and no more than 400 mm below the ceiling, and asks for an air gap equal to a 10 mm undercut on a 760 mm door. Mark the fan position and duct route on the same drawing, so a tall cabinet or shower screen does not take its place.

Electrical zones

Distances around baths and showers restrict sockets and equipment. Electrical Safety First gives the socket distance and RCD points. Plan positions with an electrician.

Heights

Record preferred basin rim, toilet seat, shower controls and shelf heights for your users. Compare with product drawings and add any raised floor or tray.

Delivery sizes

A bath that fits the room may not fit the stairs. Measure turns and landing height, as in bath sizes and access.

The tape test

  1. Mark each outline full size.
  2. Add door arcs.
  3. Walk the morning routine.
  4. Sit on a chair at the toilet position.
  5. Mime cleaning behind each item.
  6. Adjust and photograph the result.

Drawing it

Use a scale of 1:20 on squared paper. Label dimensions from two fixed walls and show wastes. Include radiator and furniture depth with handles.

When it will not fit

Choose a short projection toilet, corner basin, shower instead of bath or a different door. Check drain routes after any move, as space is useless if the waste cannot fall.

Share

Send the scale plan and photos via the contact form, emailing the drawing with your reference. Mark who uses the room and any mobility needs.

People who use the room

A family bathroom has to cope with a parent kneeling beside the bath, a child on a step and someone with stiff joints getting off the toilet. Ask each user where the current room frustrates them, and design out those points first. Space that looks generous on a plan can be taken by a laundry basket, bin, scales or radiator, so include them in the tape test. Where future mobility is a concern, keep one clear route from door to toilet and shower and allow for rails later.

Common drawing errors

Forgetting tile thickness, drawing the basin without its tap or waste depth, and showing a door without its swing account for many surprises. Check the drawing against the room once more after the old suite has gone, when true wall positions can be seen.

Questions people ask

Are there compulsory clearances in an existing home?

Ordinary like for like refits have few fixed figures, but new dwellings and some work have accessibility standards. Ask building control.

What clearance does a toilet need?

Enough to sit, stand and clean. Test it with the product outline taped on the floor.

One list, however many jobs

Add what needs fitting or replacing, tell us the postcode, then email photos.

Send my job list