Flexible tap connector replacement: check size and length, isolate, remove without twisting, fit by hand then lightly nip, avoid kinks and test for drips.
Replace a flexible tap connector with one that matches both ends, is long enough without strain and approved for drinking water. Shut the supply, fit the new hose without twisting it and check each joint.
Signs to act
- rust or broken strands in braid;
- bulges or kinks;
- crystals or green marks at crimps;
- cracked or stiff rubber;
- unknown age during other work.
Any active drip means closing the valve now.
Measure
| End | Common form |
|---|---|
| Tap end | M8, M10 or M12 stud, or half inch union |
| Pipe end | 15 mm compression or half inch BSP |
| Length | From tap to valve on gentle curve |
| Bore | Match flow needs |
Tap end sizes are explained in flexible tail sizes. Choose a product approved for drinking water: the water fittings requirements rule out materials likely to contaminate it.
Preparation
Close the servicing valve, or the stop valve if there is none. Open the tap to release pressure. Put a tray underneath and clear the cupboard.
Remove
- Hold the valve body with a spanner.
- Undo the lower nut.
- Unscrew the top end, usually by turning the spigot by its flats or by hand.
- Do not turn the tap body; if it moves, steady it from above.
- Check the O-ring did not stay in the tap.
Reaching the upper end behind a bowl may need a basin wrench or removing the tap.
Fit
Screw the tap end in by hand until seated; extra force can damage the seal. A Bristan mixer fitting sheet, for instance, says to tighten its pipes into the tap body by hand only. Connect the other end with its washer, starting by hand, then a small nip with a spanner while holding the valve. Keep the hose free of twist: if a printed line spirals, loosen and realign. Observe the minimum bend radius on the packaging.
Test
Open slowly with the tap open. Run both temperatures. Wipe and check each end after a few minutes, after an hour and next morning. A leak detector in the cupboard is a cheap extra.
Concealed positions
The water regulations require fittings to be watertight and adequately supported, and say a fitting that includes a joint must not be concealed. Do not leave a hose union behind a fixed panel or boxing that cannot be opened. Give each end a removable access panel where the basin design hides it.
Avoid
- joining two hoses;
- stretching a short one;
- wrapping a failing hose with tape;
- storing sharp or corrosive items against it.
Valve problems
If the valve will not close or drips at the spindle, replace it, see fitting service valves.
Rigid alternative
Copper connectors suit positions where hoses would rub or are exposed to damage, but need accurate lengths.
Help
Send photos of both ends, valve and tap through the contact form, emailing pictures with the reference. If water is escaping and cannot be stopped, close the stop valve first and seek immediate help.
Why hoses fail
Most problems come from installation stress: a twist under the nut, a bend too close to the end fitting, a hose pulled tight or one rubbing on a sharp edge. Chemicals stored in the cupboard can attack the braid, and long periods of damp keep corrosion going. Check that the new route avoids all of these before opening the valve.
Replace the pair
Hot and cold hoses fitted at the same time age together. Changing both during one shut-down avoids a second visit. Record the date on a label inside the cupboard and look at both whenever you clear it out. Keep the old hose only long enough to compare sizes.
Push-fit ends
Some connectors have a push-fit end. Cut the pipe cleanly, remove burrs, push to the marked depth and tug back to confirm grip, following the product instructions. Do not use them on damaged or painted pipe.
Questions people ask
How often should hoses be replaced?
There is no single interval. Replace on signs of damage or age and follow the maker.
Should I use tape on the union?
Not on a washer sealed union. The washer or O-ring makes the seal.