A high level cistern is fixed well above the pan and joined to it by a long flush pipe. Success depends on a wall that can carry the full cistern, a height matched to the supplied pipe kit and both ends lining up exactly. A low level version follows the same logic with a shorter pipe.

Check the room

Measure floor to ceiling, and allow room above to lift the cistern lid. Look for sills, cornices and sloping ceilings. A Burlington high level instruction sheet gives 2060 mm from floor to the underside of the cistern in its text, while a note on its drawing gives overall heights of 1980 to 2060 mm. Check which point your own sheet measures from, as kits vary. Confirm the pan is the one intended for high level use.

The wall

A full cistern is heavy and the pull chain adds force every time. One fitting sheet includes spacing washers for outside walls to limit thermal shock and condensation. Masonry screws suit masonry only. On a stud wall, add timber support behind the board where fixings and brackets fall. Never hang the cistern on plasterboard plugs without support designed for the load.

Setting out

  1. Set the pan in its final position and connect it to the soil pipe loosely.
  2. Mark a plumb line up from the centre of the pan inlet.
  3. Mark cistern height and fixing holes, using the supplied dimensions.
  4. Measure the flush pipe against these marks before cutting.
  5. Check for pipes and cables before drilling.

Brackets, where used, must be level with each other. On the Burlington kit the ornate brackets are decoration only: the cistern has to be fixed securely through its own rear holes.

Cistern internals

Fit the fill valve, siphon and lever or chain arm with their washers as shown. Set the water level to the marked line. WC flushing devices must not exceed the 6 litre single flush limit, the cistern needs a warning or equivalent overflow arrangement, and the inlet needs a servicing valve beside it.

Water supply

Run the supply neatly to the inlet side, with the valve at a reachable height. Exposed chrome or copper pipe becomes part of the appearance, so plan clips. A fill valve suited to your pressure matters: some run slowly at low pressure and others are noisy at high pressure.

Overflow

Old installations discharge through a pipe in the wall. Modern valves may overflow into the pan. Whichever applies, the discharge must be noticeable so that a failed fill valve is not ignored.

Flush pipe

Hang the cistern, insert the pipe with its seals at the top, join any two-part sections as the sheet instructs, and seat the lower end in the flush cone on the pan. The pipe should sit vertical without being pulled. Clip it to the wall, with a buffer where the seat could strike it.

Test

Open the valve slowly and set the level. Flush repeatedly, watching the siphon seal, pipe joints, pan cone and soil connection. Pull the chain firmly and check that the cistern does not move. Adjust chain length for comfortable reach. Look again next day.

Handle and chain

Fix the chain guide or control bracket where the sheet places it; the Burlington drawing puts it 180 mm above the pull handle. Check the handle can be reached by the people using the room and does not strike the wall or a shelf.

Period properties

Reusing an original cast iron cistern calls for checking corrosion, the lining, the siphon and whether its volume complies with current rules for the work proposed. Old paint and boards may contain hazardous materials; the HSE asbestos pages explain what to consider before disturbing them.

For fitting help, describe the wall and kit through the contact form and email photos and the instruction sheet with your reference.

Questions people ask

How high should a high level cistern go?

Use the maker's figure. One Burlington sheet gives 2060 mm from floor to the underside of the cistern, and other kits differ.

Can the flush pipe be shortened?

Many kits allow cutting to suit, but only as the instructions describe and after measuring carefully.