Tap cartridge size guide for single lever mixers: isolate, remove the cartridge, measure diameter, height, base pins and stem, then order the right part.
Identify a single lever mixer cartridge by the tap maker and model first. If those are unknown, remove the old cartridge and compare diameter, height, base layout, locating pins and stem. A part with the right diameter alone may still leak or fit badly.
Start with the maker
Look for a logo on the body or lever and search the household paperwork. Makers publish parts lists and instructions, such as this Bristan guide with cartridge access steps. Photograph the whole tap from the side and any marks under the sink.
Remove it safely
- Close hot and cold valves and open the lever to release water.
- Plug the basin or sink so screws cannot drop in.
- Prise off the indicator cap gently.
- Loosen the grub screw, usually with a small hex key.
- Lift off the lever.
- Unscrew the cover shroud by hand with cloth.
- Unscrew the retaining nut while holding the body.
- Mark which side faces forward, then lift out the cartridge.
If the nut is stuck with scale, do not twist the tap against its connections. Soak and support it.
Measure
| Feature | Record |
|---|---|
| Body diameter | Across the widest part of the main cylinder |
| Overall height | Base to top of stem |
| Stem | Shape and size where the lever fixes |
| Base | Flat or raised, port layout |
| Locating pins | Number, size and spacing |
| Seals | Fitted to base or separate |
| Stops | Any limit ring and its position |
Place the old part beside a ruler and photograph base, side and top. Diameters of 35 mm and 40 mm are common among replacement parts, with a few millimetres difference easy to misread, so use calipers if available.
Flat base or distributor base
Some cartridges sit on feet or a distributor that channels water; others have a flat bottom with seals. The two do not swap. Colour of the plastic carries no meaning between brands.
Fitting the replacement
Clean the seat of grit and scale without scratching it. Check each seal sits in place. Align the pins fully, then tighten the nut to the maker's guidance: too tight makes the lever stiff and can crack the body of the cartridge, too loose lets it weep. Refit the shroud and lever. Open valves gradually with the lever partly open to clear air.
Check the supplies too. A new cartridge on an unbalanced system needs the same check valves the tap needed before; see when a mixer needs check valves.
If problems remain
A drip from the spout after replacement may be debris under a seal or damage in the tap seat. Hot and cold reversed suggests the cartridge is turned. For poor flow, Bristan's troubleshooting points to a partly closed isolating valve, an airlock or debris in the supply pipe, so check those before ordering parts. A blocked aerator is another cause; see aerator replacement.
Other cartridge types
Separate quarter turn handles use smaller inserts, covered in quarter turn valves. Shower valves use their own cartridges, described under shower cartridge identification.
Getting a match checked
If the part cannot be identified, a new tap may be the practical route. Send the tap photos and measurements through the contact form, emailing images with your reference. Mention whether the valves under the unit close properly.
Ordering and keeping the part
Compare the new cartridge with the old one side by side before fitting: base, pins, height and stem should match visibly. If they differ, return it unused. Note the part number on a label inside the cupboard, and buy from a source that lists the tap models it fits. Keep the removed cartridge until the replacement has run without drips for a few weeks.
Questions people ask
What sizes are common?
35 mm and 40 mm are widely sold for single lever taps, but diameter alone does not guarantee a fit.
Where do I find the part number?
The tap maker's parts diagram is best. Match it by model name or code.